Webel vs SysPhS-1.1: Suggest SysPhSLibrary should explicitly support physical interactions with multiple conserved quantity flows. Example: Compressible fluid with mass and heat transfer.
Webel vs SysPhS-1.1: Suggest SysPhSLibrary should support Heat and FlowingHeat as conserved quantities with HeatFlowElement interface block and HeatFlowRate value type.
Webel vs SysPhS-1.1: Suggest SysPhSLibrary should support Mass and FlowingMass as conserved quantities (for compressible fluids) with MassFlowElement interface block and MassFlowRate value type.
Fluid Connectors - ThermoFluid Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 06. Connectors Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Internal Block Diagram (IBD)
Fluid Connectors - Compressible Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 06. Connectors Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Internal Block Diagram (IBD)
Fluid Connectors - Incompressible Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 06. Connectors Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Internal Block Diagram (IBD)
SimpleDomains - Thermal Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 06. Connectors Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Internal Block Diagram (IBD)
SimpleDomains - Rotational Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 06. Connectors Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Internal Block Diagram (IBD)
SimpleDomains - Translational Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 06. Connectors Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Internal Block Diagram (IBD)
SimpleDomains - Electrical Gallery Tutorial TRAIL: SysML+SysPhS vs Modelica By Example in MagicDraw/Cameo SysML [tested with the Wolfram SystemsModeler for Modelica] Section 06. Connectors Slide kind hybrid diagram SysML Block Definition Diagram (BDD) SysML Internal Block Diagram (IBD)
SysML+SysPhS: Flows: If you intend to use a Classifier to type the itemProperty of an ItemFlow on a Connector for a physical interaction you MUST use a Block (not a ValueType or Signal) so your can extend ConservedQuantityKind.
Overview of two SysPhS-style physical interaction Port types Gallery Tutorial TRAIL: SysML: Simple model of an air conditioner with a refrigerant cycle and StateMachine driven by Activities in MagicDraw/Cameo Section Slide kind SysML Package Diagram
BDD: Figure 39: Electrical blocks, ports & component properties Gallery Tutorial TRAIL: SysPhS-1.1 Annex A examples in MagicDraw/Cameo SysML vs Modelica (Wolfram SystemsModeler) Section Annex A.2: Electric Circuit Slide kind SysML Block Definition Diagram (BDD)
PhSVariable: [3] isConserved may be true only when isContinuous is true and the stereotyped property is on a block specialized from ConservedQuantityKind (see Subclause 11.2.2). Source SysPhS-1.1
Figure 31: Elements for physical interaction Gallery Tutorial TRAIL: SysPhS-1.1 specification body figures in MagicDraw/Cameo SysML vs Modelica [using Wolfram SystemsModeler] Section Slide kind SysML Package Diagram
Figure 23: Ports for physical interaction in SysML Gallery Tutorial TRAIL: SysPhS-1.1 specification body figures in MagicDraw/Cameo SysML vs Modelica [using Wolfram SystemsModeler] Section Slide kind hybrid diagram SysML Block Definition Diagram (BDD)